BRAND | ProMinent |
Product | 1002534 RH -Elektrode RHER-Pt -SE |
Description | ORP sensor |
Internal code | IMP411651 |
Weight | 1 |
Custom code | 90278930 |
Technical specification | for use in aqueous contaminated media which contain solids, and media with low conductivity. Applications include wastewater, cooling water, process water, chemical processes and paper making. ORP electrode: platinum Temperature: 0... 80°C max. pressure: 6.0 bar conductivity: min 50 µS/cm Screw-in thread: PG 13.5 Electrical connection: SN6 (S8) Sensor shaft diameter: 12 mm Installation length: 120 mm Diaphragm: Dirt-repellent PTFE ring diaphragm Electrolyte: gel containing potassium chloride with salt stock Note: *********** For precise measurements, a regular validation of the sensor is required recommended with ProMinent quality buffer solutions! |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for ProMinent - 1002534 RH -Elektrode RHER-Pt -SE ORP sensor number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Portugal Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Sealing ring
Diaphragm
dosing membrane
Solenoid Metering Pump
magnetic dosing pump
BT4B Magnetdosierpumpe beta 4b
Dosage pump
FLOW METER
Chemical Dosing pump
Dosing pump
METERING PUMP
PES-Messzelle
Pump
Flowmeter with analogue signal
delta (R) solenoid diaphragm dosing pump
solenoid
Pump
PUMP,DOSING,SOLENOID
solenoid
Barrel Pump
Barrel pump
DOUBLE BALL VALVE
Dosing pump