(310035142130) LF 4213-C0,5-00 - Martens Portugal Sales

BRAND Martens
Product (310035142130) LF 4213-C0,5-00
Description Conductive 4-electrode Conductivity measuring cell with integrated sensor PT1000 Cell constant C = 0.5 Conductivity in the range 0 ... 20us / cm to 0 ... 500mS / cm max. Working temperature 60 ° C Compressive strength max. 16bar / 22 ° C Electrical connection via 8-pol.Rundsteckverbinder, IP67 Cell body in PVC-U according to DIN 8061/8062 Measuring cell head made of cast resin Electrode graphite for installation in Flow assembly DFA 32 diameter 25mm Installation / total length of 73 / 112mm no option
Inner code IMP328
Weight 1

Please Contact Us to Order to offer best price and delivery time for Martens - (310035142130) LF 4213-C0,5-00 :product_tech_spec model number, also you may ask some other model number is well. We can offer best price, and delivery time with wide products distribution network in Portugal Industrial products Market.

WE SELL ONLY ORIGINAL AND NEW PRODUCTS

Our company is not an authorized distributor and manufacturer's representative of the brands shown on the website. Private brand names shown on this site and trademarks are the property of their respective owners

More products of Martens

(310035142130) LF 4213-C0,5-00

Conductive 4-electrode Conductivity measuring cell with integrated sensor PT1000 Cell constant C = 0.5 Conductivity in the range 0 ... 20us / cm to 0 ... 500mS / cm max. Working temperature 60 ° C Compressive strength max. 16bar / 22 ° C Electrical connection via 8-pol.Rundsteckverbinder, IP67 Cell body in PVC-U according to DIN 8061/8062 Measuring cell head made of cast resin Electrode graphite for installation in Flow assembly DFA 32 diameter 25mm Installation / total length of 73 / 112mm no option

100019 TV500L-100-5

(Commodity code: 90303310 Order code: TV500L-100-5 Isolation Amplifier Type: TV500L Inputs: 0 / 4-20 mA and 0 / 2..10 V DC Outputs: 0 / 4-20 mA (max. 400 ohms), 0 / V 2..10 Characteristic: Rising Isolation: between Input / output / supply voltage Auxiliary voltage: 24 V DC ± 15% Working temperature: -10 .. + 50 ° C Standard housing: 22.5 mm wide for TS35, Terminal connection)

100188 TW500-2-1

(Commodity code: 90303310 Order code: TW500-2-1 potential Breaks Type: TW500 Device version: 2-channel Input: 0 (4) .. 20 mA Voltage drop: <2.7 V DC Output: 0 (4) .. 20 mA without power supply: acc. IEC 61158-2, Bus voltage: 9..32 V DC Insulation voltage: 630V according to VDE 0110 / G3, Test voltage 4 kV Working temperature: -20 .. + 60 ° C Standard housing: 22.5 mm wide for TS35, Terminal connection)

100536 ST500-10-5

Product number: 90303310 Order code: ST500-10-5 Universal Supply Isolation Amplifier Type: ST500 Inputs: 0 / 4-20 mA and 0 / 2..10 V DC Outputs: 0 / 4-20 mA (max. 1 kOhm), simultaneously 0 / V 2..10 Isolation: between Input / output / supply voltage Supply voltage: 10,8..30 V AC / DC Standard housing: 22.5 mm wide for TS35, terminal connection

100642 90303310 H2CM-M3/M4-00

Lot number: 90303310Bestellschlüssel: H2CM-M3 / M4-00Heizstrom monitoring module Type: H2CMFunktion: Automatic detection desHeizstromes through teach-in function Measuring range: 1..80 A AC via integr.StromwandlerAlarmausgang: PNP transistor open collector, max. 50 mA (short-circuit) of supply: 10..30 V DCArbeitstemperatur: -10 .. + 60 ° CMontage directly on the terminals of the SSR relay terminal screws: DIN thread M3 / M4Option: No Option

2055810019B6

Warennummmer: 90251920 8100 / A.1.9.250.G1 / 2A.BK.400 ° C RTD 1x Pt100 according to DIN EN 60571 Class B in 2-wire circuit Protective tube d = 9mm Measuring sleeve: Plan 1.4571 Temp Probe -50 ... + 400 ° C

310003000450

DC / DC converter NG1000-4-5 output 5 ... 24V DC, max. 2.0A Input 24V DC ± 20% stabilized, short-circuit in 55mm standard housing

310024500100 TV500-10-0

Product number: 90303310 TV500-10-0 Universal isolation amplifier Inputs 0 / 4-20 mA and 0 / 2-10 V Outputs 0 / 4-20 mA; Burde max. 1kOhm simultaneously 0 / 2-10V switchable With separation galv. Between Input / output / supply voltage Auxiliary voltage 100 ... 265V AC in 22.5mm Normgehause for TS35 terminal connection

310040EX2R00

Warennummmer: 90303310 TS500Ex-ia-2R 0 Isolating amplifier 2-channel with relay output Input for switching contacts, Namur initiators or optocoupler intrinsically safe acc. ATEX II (1) G [Ex ia] IIC / IIB, ATEX II (1) D [Ex iaD]

320017100000

Warennummmer: 90303310 SD9648-1-0-0-00 Alarm message display Activation by floating Contacts or 0 / 24V signals New value message internal or external acknowledgment LCD text display with backlighting 2 lines of 16 characters * 6.5mm high Text length max. 64 characters built-in alarm relay (relay Wechler) 20 digital inputs o h n e RTC Auxiliary voltage 230V AC ± 10% no options DIN case 96x48mm Depth 100mm Front protection IP65

8100/A.1.9.250.G1/2A.BK.400°C

RTD 1x Pt100 according to DIN EN 60571 Class B in 2-wire circuit Protective tube d = 9mm Measuring sleeve: Plan 1.4571 Temp Probe -50 ... + 400 ° C Installation length: 250mm Measuring insert length: 292mm Thread: G1 / 2A 1.4571 Connection: B head to DIN 43729

CT500-30-0

AC Transmitter CT500

CT500-30-0

Wechselstrom-Messumformer

CT500-30-5

AC Transmitter

DA9648-4-00-0-01

Digital Ammeter

DA9648-6-00-0-05

INPUT: 0 ... 10 VDC Display: 0 ... 19990 / H

DC30-D3

Load circuit max. 30V DC / 3A *** note polarity! *** Also for inductive load signs Driving circuit 3-24V DC with LED dir. Isolation Input / Output 12mm Geh.f.Tragschienenmontage

DP9648-2-0-1-10

Heat indicator

EP9648-1-15-0-00

Economy Panelmeter

EP9648-1-15-0-00

Economy Panelmeter

EP9648-1-15-5-00

Economy-PanelMeter

EP9648-6-15-0-00

INPUT: 0-10V DC DISPLAY: 0 ......... .19990 / h

FS222

Sensor

HT022536410

DA9648-1-12-100

LF4213A-C0,5-00

Conductivity Cell Type: LF4213A Design: field mounting Measuring principle: 4-electrode conductively Range of application: flow cell for Tube outside diameter of 20 mm to 63 mm Temperature measurement: an integrated Pt1000 sensor DIN IEC 751, Class A Cell constant: C = 0.5 Conductivity measuring range: 0 to 20 ĩS / cm to 0 .500 mS / cm Operating temperature: 0 ° C .60 Compressive strength: max. 16 bar at 22 ° C Process connection: Built-in flow-through fitting DFA32 Built-in / Overall length: 101/153 mm Process material: graphite electrodes, PVC-U to DIN8061/8062 Electrical connection: 8-pin. Circular connector M12x1 IP67, Material nickel-plated brass Option: no option

Contact us for request